Product Center

33kv Live Tank SF6 Outdoor Circuit Breaker 630A 1250A 1600A

Short Description:

The product uses SF6 gas as the arc extinguishing and insulating medium, andadopts the most advanced self-energy arc extinguishing technology in the world. It has the characteristics of long electricallife, low operating power, low noise, high reliability, and moderate price.


Product Detail

Product Tags

We have now numerous great personnel members good at advertising, QC, and working with kinds of troublesome dilemma from the creation course of action for 33kv Live Tank SF6 Outdoor Circuit Breaker 630A 1250A 1600A, Our clientele mainly distributed within the North America, Africa and Eastern Europe. we are able to supply premium quality goods with the incredibly aggressive price tag.
We have now numerous great personnel members good at advertising, QC, and working with kinds of troublesome dilemma from the creation course of action for SF6 Outdoor Circuit Breaker 630A, We guarantee that our company will try our best to reduce customer purchase cost , shorten the period of purchase , stable products quality , increase customers’ satisfaction and achieve win-win situation .

Specification

Rated Voltage 36KV
Rated Current 800/1600/2500 / 3150/4000
Mechanical Life 10000 times
SF6 Gas rating(Gage pressure whenthe 20 °C) 0.45Mpa
Lock pressure(Gage pressure whenthe 20 °C) 0.4Mpa
Minimum ambient temperature -40°C
Rated short circuit duration 4S

Parameter

Item

 Unit 

Data

Maximum Voltage

KV

40.5

Rated voltage

KV

36

Rated Current

A

1250

Lightning Impulse withstand

Voltage (Full Crest Value)

KV

185/215 (fracture)

Power Frequency Withstand

Voltage

KV

95/118 (fracture)

Rated short-circuit breaking

current

KA

31.5

Rated short circuit closing

current (peak)

KA

80

Rated out-of-step breaking

current

KA

8

SF6 gas pressure rating (20℃

gage pressure)

Mpa

0.45

Closure pressure(20℃ gage

pressure)

Mpa

0.4

yearly gas leakage rate

%/year

≤0.1

SF6 gas moisture content(20℃)

ppm(v/v)

≤150

Turn-off time (under rated

operating voltage)

ms

≤50

Closing time (under rated

operating voltage

ms

≤100

Conductive loop resistance of each phase

μΩ

≤80

Rated operation sequence

V

Points—03s—or points-180s—or points

Control Voltage

KG

DC;110V

DC;220V

SF6 gas weight

KG

6

Breaker weight (including

operating mechanism

 

800

0731092027

Detail Image

1 (1)
1 (2)
1 (3)
1 (4)
LW36-40.5 Outdoor AC 50HZ sulfur hexafluoride circuit breakers for three-phase power system of outdoor equipment, for industrial and mining enterprises, power plants and substations for control and protection. The product can be frequent operation can be used as contact breakers and meet the capacitor, circuit breaker with reactor group. Containing a current transformer for measurement and protection, can directly replace SW2-35-type breaker, with various models of transition support alternative multi-oil circuit breakers, 35kV power system is the ideal non-oil circuit device.

LW36-40.5 circuit breaker equipped with the CTl4-A type of AC-DC dual-spring mechanism. 1.3 LW36-40.5-type circuit breakers meet the IEC 62271.


  • Previous:
  • Next:

  • Write your message here and send it to us