Our eternal pursuits are the attitude of “regard the market, regard the custom, regard the science” and the theory of “quality the basic, belief the very first and management the advanced” for Factory Customized Outdoor High-Voltage Disconnect Switch Hgw9-10, In addition, we would properly guideline the shoppers about the application techniques to adopt our products and solutions as well as the way to select appropriate materials.
Our eternal pursuits are the attitude of “regard the market, regard the custom, regard the science” and the theory of “quality the basic, belief the very first and management the advanced” for China Fuse Cut out and Expulsion Fuse, Actually need to any of those objects be of interest to you, make sure you allow us to know. We’ll be delighted to present you a quotation on receipt of one’s comprehensive specs. We’ve our individual specialist R&D enginners to meet any of the requriements, We look forward to receiving your enquires soon and hope to have the chance to work together with you inside the future. Welcome to take a look at our organization.
Parameter
GW9-12 old type / GW9-15 new
HGW9-12 old type / HGW9-15 new
Parameter
Parameter name | Unit | Parameter value | |||
Rated voltage | kv | 12 | |||
Maximum operating voltage | kV | 12 | |||
Rated frequency | Hz | 50/60 | |||
2S thermal stability current KA (effective value) | A | 200 | 400 | 630 | |
Dynamic stability current KA (effective value) | kA | 6.3 | 12.5 | 20 | |
Rated lightning impulse withstand voltage | Relatively | kV | 105 | ||
Between fractures | kV | 120 | |||
Rated 1min power frequency withstand voltage | Relatively | kV | 40 | ||
Between fractures | kV | 47 | |||
Creepage distance | mm | 300 | |||
Mechanical life | N | 2000 |
GW9-12 old type / GW9-15 new
GW9-12 OLD TYPE | |||||
Type | Rated voltage (kv) | Rated current (A) | Limit passing current (KA) | 10s Heat steady current | |
Peak | RMS | ||||
GW9-12W/200 | 12 | 200 | 5 | 9 | 5 |
GW9-15W/400 | 12 | 400 | 21 | 15 | 10 |
GW9-15W/400 | 12 | 630 | 35 | 25 | 14 |
—————————————————————————————————————————————————————————
GW9-12 NEW | |||||
Type | Rated voltage (kv) | Rated current (A) | Limit passing current (KA) | 10s Heat steady current | |
Peak | RMS | ||||
GW9-15W/200 | 15 | 200 | 5 | 9 | 5 |
GW9-15W/400 | 15 | 400 | 21 | 15 | 10 |
GW9-15W/630 | 15 | 630 | 35 | 25 | 14 |
HGW9-12 old type / HGW9-15 new
HGW9-12 OLD TYPE | |||||
Type | Rated voltage (kv) | Rated current (A) | Limit passing current (KA) | 10s Heat steady current | |
Peak | RMS | ||||
HGW9-12W/200 | 12 | 200 | 5 | 9 | 5 |
HGW9-15W/400 | 12 | 400 | 21 | 15 | 10 |
HGW9-15W/630 | 12 | 630 | 35 | 25 | 14 |
—————————————————————————————————————————————————————————
HGW9-15 NEW | |||||
Type | Rated voltage (kv) | Rated current (A) | Limit passing current (KA) | 10s Heat steady current | |
Peak | RMS | ||||
HGW9-15W/200 | 15 | 200 | 5 | 9 | 5 |
HGW9-15W/400 | 15 | 400 | 21 | 15 | 10 |
HGW9-15W/630 | 15 | 630 | 35 | 25 | 14 |
Our eternal pursuits are the attitude of “regard the market, regard the custom, regard the science” and the theory of “quality the basic, belief the very first and management the advanced” for Factory Customized Outdoor High-Voltage Disconnect Switch Hgw9-10, In addition, we would properly guideline the shoppers about the application techniques to adopt our products and solutions as well as the way to select appropriate materials.
Factory Customized China Fuse Cut out and Expulsion Fuse, Actually need to any of those objects be of interest to you, make sure you allow us to know. We’ll be delighted to present you a quotation on receipt of one’s comprehensive specs. We’ve our individual specialist R&D enginners to meet any of the requriements, We look forward to receiving your enquires soon and hope to have the chance to work together with you inside the future. Welcome to take a look at our organization.