LSOLATING SWITCH

GW4-40.5 series light torque maintenance type outdoor high-voltage disconnector is an outdoor high waist electrical equipment with a frequency of less than 50Hz-60Hz. It is used for replacement under high-voltage no load, and for electrical isolation between the overhauled high-voltage bus, circuit breaker and other electrical equipment and live high-voltage lines. It can also be used to open and close very small capacitive current and inductive current.

According to the use area: ordinary type, pollution attached type and plateau type.
Whether the grounding switch is connected or not: ungrounded, single grounding and double grounding.

This series of disconnectors meet the requirements specified in GB1989-89 AC high voltage disconnectors, IEC1129 (1984), AC disconnector grounding switches and IEC694 (1980) common terms for high voltage switchgear and control equipment. This series of products have good seismic resistance and meet the requirements of 9 degrees of earthquake (horizontal acceleration 4.9m/s2 and vertical acceleration 2.45m/s2).

For more information about GW4-40.5 disconnect switch, please contact us.

TECHNICAL PARAMETER

Parameter
35kV series 01
35kV series 02
35kV series 03
Parameter

 

Parameter name Unit   Parameter value
Rated voltage kv 35
Maximum operating voltage kV 40.5
Rated frequency Hz 50/60
Rated current A 630 1250 2000 2500
2S thermal stability current KA (effective value) kA 20 31.5 40 46
Dynamic stability current KA (effective value) kA 50 80 100 104
Rated lightning impulse withstand voltage Relatively kV 185
Between fractures kV 215
Rated 1min power frequency withstand voltage Relatively kV 95
Between fractures kV 118
Creepage distance mm 900
Rated longitudinal mechanical load of terminal N 750(980)
Matching mechanism CJ6, CJ11M-G maintenance free electric operating mechanism or CS11-1, CS11, CS8-6D manual mechanism
35kV series 01

35kV series-01

35kV series 02

35kV series-02

35kV series 03

35kV series-03

PELATED PRODUCTS

PRODUCT DETAILS

>>   Action principle                                                                                                                                                        / 动作原理
>>   Hidden danger                                                                                                                                                         / 安全隐患
>>   Installation scenario                                                                                                                                                / 安装场景
>>   Product characteristics                                                                                                                                           / 产品特性
>>   Service conditions                                                                                                                                                   / 使用条件
>>   Why choose us                                                                                                                                                        / 为什么选择我们

>> GW4-40.5 Disconnector

1. The disconnector is of double column horizontal rotary structure
Each pole is composed of three independent monopoles, and each monopole is composed of base, insulating pillar and conductive part. Each pole has two insulating pillars respectively fixed on the bushings at both ends of the base and connected by connecting rods. Each insulating pillar can rotate horizontally with a rotation angle of 90 °. The insulating pillar is equipped with conductive wiring base and left and right contacts. The left and right contacts are in contact between the two insulating pillars through the conductive plate. The structural type, base, post insulator and other components of products with different current specifications are the same, but the conductive circuit is slightly different.

2. Structure of grounding switch
The static contact of the grounding switch is fixed on the conductive pipe of the disconnector, and the moving contact is installed on the end of the grounding knife steel pipe on the base.

3. Structure of manual mechanism
The manual mechanism is divided into CS11-1, CS11 and CS8-6D. Its operating handle rotates horizontally with a rotation angle of 90 °. CS8-6D is equipped with interlocking device to ensure the operation according to the specified procedure (main opening - ground closing - ground opening - Main closing).

4. Mechanical interlocking of disconnector and grounding switch
The mechanical interlocking of disconnector and grounding switch is partially realized through the interlocking panel on cs8-6d manual mechanism.

5. Structure of electric mechanism
For the structure of CJ6 electric operating mechanism or CJ11M-G surface maintenance electric mechanism, see its installation and operation manual.

GW4-30.5-01
function

Safety  protection   //  Corrosion resistance  //  Outdoor  rainproof  //  Long life  //  Excellent material

>> Action principle

The operating mechanism of the disconnector is connected with the driving stage of the disconnector through the connecting pipe. The main shaft of the mechanism rotates by 90 °, driving the insulating pillar of the driving stage to rotate by 90 °, and the connecting rod in the base drives the insulating pillar on the other side to rotate in the opposite direction to realize the opening and closing action. The driving stage drives the other two driven poles to rotate through the inter pole linkage pipe, so as to maintain the three-phase synchronous action. The auxiliary switch in the mechanism is connected with the main output shaft of the mechanism and sends the corresponding opening and closing signal in the opening and closing position.

The main shaft of the three-phase grounding switch is connected with the horizontal connecting pipe through the joint, the handle of the operating mechanism rotates horizontally by 90 °, and the horizontal connecting pipe is driven to rotate through the connecting rod to realize the opening and closing action of the grounding switch.

The operating mechanism is connected with the main shaft of the disconnector and grounding switch through the connecting pipe. The cs8-6d manual mechanism is equipped with the disconnector with grounding knife, and its output interlocking board ensures the operation according to the specified procedure (main opening - Grounding closing - Grounding opening - Main closing).

>> Hidden danger

The use of inferior disconnector will lead to porcelain bottle fracture fault and overheating of conductive circuit. During operation, the spring will be compressed for a long time due to static contact finger compression.
If the working current is large and the temperature rise exceeds the allowable value, its elasticity will deteriorate and a vicious circle will eventually cause burning loss and endanger life safety!

GW9-12-hidden danger

>> Installation scenario

Hydropower station                                                                                                                                                                                #1
Factory and mining enterprises                                                                                                                                                            #2
Ring network power supply                                                                                                                                                                   #3
Petrochemical Enterprises                                                                                                                                                                     #4

>> Product characteristics

01.Exquisite material safety protection                                                                                                                                            ......./03
02.Silver Plated Red Copper isolating knife switch                                                                                                                         ......./03
03.High performance and long life                                                                                                                                                    ......./03

>> Service conditions

Normal-service-conditions

1. Altitude: 1000-3000m;
2. The ambient temperature is not higher than + 40 ℃ and not lower than - 30 ℃ (not lower than - 40 ℃ in alpine areas);
3. The wind pressure shall not exceed 700pa (equivalent to the wind speed of 34m / s);
4. The seismic intensity shall not exceed 8 degrees;
5. The icing thickness shall not be greater than 10mm;
6. The installation site shall be free of inflammable and explosive dangerous goods, chemical corrosion and violent vibration;
7. Pollution grade of post insulator: ordinary type grade 0 and anti pollution type grade II.

>> Why choose us

DESIGN SERVICES

Packaging design and improved product mix have a history of more than 20 years. It is the most important to establish and maintain the unique characteristics and style of products

PRODUCT SAMPLING

Mass production can only start after you approve it

DEVELOPMENT

New product development, different market characteristics and commitment to international trade facilitation, credibility and transparency

AFTER-SALE SERVICE

Customer feedback, actively looking for solutions to problems, professional technical guidance and long-term after-sales service

奖状

COMPANY INTRODUCTION

公司图片
Company profile

       Lawrence Electric Co., Ltd. is a high-tech enterprise focusing on power transmission and distribution products, providing customers with one-stop service of power transmission and distribution products.

        It mainly produces and sells lightning arrester, insulator, fuse, isolation / load switch, SF6 / vacuum circuit breaker, power supply fittings, optical cable fittings, switch cabinet and other transmission and distribution products. The company has production bases and sales centers in Jiangxi, Zhejiang, Uganda, Tanzania and other places.

Nature of Business

        Our products have operated safely in the power supply systems of more than 20 countries and regions around the world for more than 10 years. They are also qualified suppliers of China State Grid and China Southern Power Grid. At present, they have gained a good reputation in the field of power system in the world.

world

        We have received high-quality product recommendation letters from power supply companies in Kenya, Uganda, Tanzania, Zambia, Guinea, Ghana, Togo, Mozambique, Nepal, Guyana, Myanmar and other countries and regions.

Real shooting factory

factory

Conformity inspection

test

Ehibition

xhibition

22

------------------------------------------------------------

企业愿景:成为全球输配电集成供应商
OUR VISION: ONE STOP SERVICE FOR THE GLOBAL DISTRIBUTION AND SUBSTATION ELECTRICAL MATERIALS.
企业价值观:以卓越品质立企业之本,以优质服务得民众之心。
OUR VALUE: SUPERIOR QUALITY BUILDS THE FOUNDATION, EFFICIENT SERVICE WINS CUSTOMER’S CREDIT.
企业精神:团队协作,勇于开拓,持之以恒,共创辉煌。
OUR SPIRIT: FOCUS ON TEAMWORK AND COLLABORATION
BRAVE IN EXPLORATION AND CREATIVITY
NEVERT GIVE UP ON ANY COMPANY PERSONNEL
TO CREATE A BRILLIANT TOMORROW TOGETHER
员工行为:倾听,微笑,赞美,坚守承诺,感恩。
CONDUCT CODE: LISTEN, SMILE, PRAISE, APPRECIATE
企业责任:为客户创造价值,为员工创造美好生活,为社会做出应有贡献。
OUR RESPONSIBILITY: MAXIMIZE CUSTOMER’S PROFIT, CREATE GREAT CONDITION FOR STAFF,
MAKE CONTRIBUTIONS TO THE WHOLE WORLD !。

PACKAGING AND TRANSPORTATION

Packaging-and-transportation

SHOPPING INSTRUCIONS

Warranty

We are aware of the quality assurance. If you have any question, please contact the customer service, so as to ensure that you can use them and solve your worries.

About Delivery

The production cycle is generally 10 to 30 working days depending on the product. In case any urgent materials please contanct with us for fast delivery.